• Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us
  • Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us

Scoreflex

  • Home 
  • Future portfolio 
  • Our Brands 
  • Scoreflex

Scoreflex

  • Print
  • Email
Scoreflex

Recommended Applications:

  • Lesion preparation for stents
  • In Stent Restenosis
  • Bifurcation lesions
  • Smaller vessels
  • Ostial Lesions
  • Diffuse disease

Effective Focused Force Dilatation with Dual Wire System

The dual wire system creates a focal stress pattern to facilitate effective controlled plaque fracture at low resolution pressure.

X-Flex tip and TiFo Folding for Low Crossing Profile

Splendid Crossability

X-Flex tip and TiFo Processing enable unsurpassed crossability.

Flex Zone
Flexible soft tapered tip allows for smooth lesion entry.

Transit Zone
Transit zone provides a balanced support to guide the balloon to pass through the lesion.

Support Zone
Support zone secures the guidewire exit positioning and assists in pushability of the device.

Tight Fold processing results in a slender 
primary profile for enhanced crossability 
through tight lesions.

Designed for Unbeatable Trackability

Soft balloon material combined with elastic nitinol integral wire exhibit exceptional trackability.

Procedural Steps

 

Step 1

Advance a standard guidewire to cross through the target lesion.

 

Step 2

Advance Scoreflex over the guidewire and cross the target lesion. Position the dilatation section of the balloon within the stenosis.

 

Step 3

Begin inflation of Scoreflex at 2 atm and hold at this pressure for 10-20 seconds. Gradually increase pressure in 1 atm steps until the target balloon diameter is achieved. Hold at the final pressure for 20 seconds.

 

Step 4

Withdraw the deflated Scoreflex catheter once the desired result is achieved.

Technical Drawing (Click on the picture to enlarge)


Compliance Chart

 (mm)   PRESSURE (atm)
  4 6* 8 10 12 14 16** 18 20
    NP         RBP    
 
2.0   1.96 2.00 2.04 2.08 2.12 2.16 2.20 2.23 2.27
2.5 2.45 2.50 2.55 2.60 2.65 2.70 2.75 2.80 2.86
3.0 2.94 3.00 3.05 3.11 3.17 3.22 3.28 3.34 3.39
3.5 3.43 3.50 3.57 3.63 3.70 3.76 3.83 3.90 3.96
4.0 3.92 4.00 4.08 4.15 4.23 4.31 4.38 4.46 4.53
                   

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  10 15 20
     
2.0 620-103-1 620-153-1 620-203-1
2.5 625-103-1 625-153-1 625-203-1
3.0 630-103-1 630-153-1 630-203-1
3.5 635-103-1 635-153-1 635-203-1
4.0 640-103-1 640-153-1 640-203-1
Tweet
back to top

Company Profile

conpany profile png

About Nebras

Contact us
Nebras Co. Ltd. P.O. Box 1235 Amman 11821 / Jordan Telephone no. +962 6 55 20 55 4 Email: عنوان البريد الإلكتروني هذا محمي من روبوتات السبام. يجب عليك تفعيل الجافاسكربت لرؤيته.
Welcome To Our Website
Nebras aims to be the market leader in the field of Biomedical Equipment and Medical Supplies to supply healthcare organizations with latest innovations, best quality…
Partnership
For supplying of pharmaceuticals from different manufacturers in Jordan •Levant - Romania For supplying pharmaco- herbal products 
Future portfolio
•Pharmaceutical products (most of therapeutic groups) •Food supplements •Personal care •Dental care •Nutrients •Medical supplies
Vision & Mission
•NEBRAS Vision:    To be one of the leading marketing and distributing companies in the MENA region. •NEBRAS Mission :    To market and distribute…

Peptest

0999

Professional Staff

We have a proffessional in marketing and sales and distribution.

 

 
 
 

 
 
© Copyright 2015 - Nebras. All rights Reserved
Developed By Just Click Solutions 
Back top