Sapphire

 Sapphire Coronary Dilatation Catheter is a balloon that combines advanced new technologies for ultimate crossability. The Sunflex tapered tip is superbly engineered for smooth lesion accessability and ultra low tip profile. With specially formulated Slidematrix dual coating and the enhanced TiFo processing, Sapphire is ideal for lubricious crossing.

The 1.25 mm balloon offers predictable crossability for your most challenging lesions. A truly well balanced performance from hub to tip. The smooth transition zone enhances trackability in tortuous anatomy and enhances visibility from dye injection in complex procedures together with resistance against buckling and kinking which maximizes pushability. The Sapphire 1.25 mm is the first low profile balloon available in 5 mm lengths.

  • Strengthened hypotube and thinner distal shaft
  • ”Zero” transition between the tip and wire for smoothest entry profile


”Zero” transition

Sunflex Tip for Smooth Lesion Accessability

Sunflex tip is superbly engineered to give a perfect balance between flexibility and kink resistance. The tapered soft tip combined with advanced laser welding technology provides the most competitive tip entry profile of 0.016" reducing fish mouthing.

TiFo Folding for Enhanced Crossability in the Tightest Lesions

Tight Fold processing results in a slender primary profile for enhanced crossability through tight lesions.

Slidematrix Dual Coating for Superb Crossability

Slidematrix coating provides an optimal balance providing lubricious crossing and minimizing watermelon seeding. Hydrophilic coating is applied on the tip and Invio coating is applied from the balloon to the proximal exit marker.

Kissing

Technical Drawing (Click on the picture to enlarge)


 

 

Compliance Chart

 (mm)   PRESSURE (atm)
  3 4 5 6* 7 8 9 10 11 12 13 14 15 16** 17 18 19 20
        NP                   RBP        
 
1.25   1.19 1.21 1.23 1.25 1.27 1.29 1.31 1.34 1.36 1.38 1.40 1.42 1.44 1.47 1.49 1.51 1.53 1.55
1.5 1.33 1.40 1.45 1.50 1.54 1.57 1.60 1.63 1.65 1.67 1.69 1.71 1.73 1.75 1.76 1.78 1.79 1.80
2.0 1.84 1.91 1.96 2.00 2.04 2.07 2.09 2.12 2.14 2.16 2.18 2.20 2.21 2.23 2.24 2.25 2.27 2.28
2.25 2.09 2.15 2.21 2.25 2.29 2.32 2.35 2.37 2.39 2.41 2.43 2.45 2.47 2.48 2.49 2.51 2.52 2.53
2.5 2.32 2.39 2.45 2.50 2.54 2.58 2.61 2.63 2.66 2.68 2.70 2.72 2.74 2.76 2.77 2.79 2.80 2.82
2.75 2.53 2.62 2.69 2.75 2.80 2.84 2.88 2.91 2.95 2.97 3.00 3.02 3.05 3.07 3.09 3.10 3.12 3.14
3.0 2.77 2.87 2.94 3.00 3.05 3.10 3.13 3.17 3.20 3.23 3.26 3.28 3.30 3.32 3.34 3.36 3.38 3.40
3.25 3.01 3.11 3.19 3.25 3.30 3.35 3.39 3.43 3.46 3.49 3.52 3.55 3.57 3.59 3.62 3.64 3.65 3.67
3.5 3.21 3.33 3.42 3.50 3.57 3.62 3.67 3.72 3.76 3.79 3.83 3.86 3.89 3.91 3.94 3.96 3.99 4.01
4.0 3.67 3.81 3.91 4.00 4.07 4.14 4.19 4.24 4.29 4.33 4.37 4.41 4.44 4.47 4.50 4.53 4.55 4.58
                                     

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  5 8 10 12 15 20 30
     
1.25 103-1205 103-1208 103-1210 - 103-1215 - -
1.5 - - 103-1510 103-1512 103-1515 103-1520 -
2.0 - - 103-2010 103-2012 103-2015 103-2020 -
2.25 - - 103-2210 - 103-2215 103-2220 -
2.5 - - 103-2510 103-2512 103-2515 103-2520 103-2530
2.75 - - 103-2710 - 103-2715 103-2720 -
3.0 - - 103-3010 103-3012 103-3015 103-3020 103-3030
3.25 - - 103-3210 - 103-3215 103-3220 -
3.5 - - 103-3510 - 103-3515 103-3520 103-3530
4.0 - - 103-4010 - 103-4015 103-4020 -
Tweet
back to top

Company Profile

conpany profile png

About Nebras

Contact us
Nebras Co. Ltd. P.O. Box 1235 Amman 11821 / Jordan Telephone no. +962 6 55 20 55 4 Email: عنوان البريد الإلكتروني هذا محمي من روبوتات السبام. يجب عليك تفعيل الجافاسكربت لرؤيته.
Welcome To Our Website
Nebras aims to be the market leader in the field of Biomedical Equipment and Medical Supplies to supply healthcare organizations with latest innovations, best quality…
Partnership
For supplying of pharmaceuticals from different manufacturers in Jordan •Levant - Romania For supplying pharmaco- herbal products 
Future portfolio
•Pharmaceutical products (most of therapeutic groups) •Food supplements •Personal care •Dental care •Nutrients •Medical supplies
Vision & Mission
•NEBRAS Vision:    To be one of the leading marketing and distributing companies in the MENA region. •NEBRAS Mission :    To market and distribute…

Peptest

0999

Professional Staff

We have a proffessional in marketing and sales and distribution.

 

 
 
 

 
 
© Copyright 2015 - Nebras. All rights Reserved
Developed By Just Click Solutions 
Back top