• Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us
  • Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us

Super User

  • Home 
  • Vision & Mission 
  • Super User
Super User

Super User

Scoreflex

الأحد, 19 نيسان/أبريل 2015 13:36
Scoreflex

Recommended Applications:

  • Lesion preparation for stents
  • In Stent Restenosis
  • Bifurcation lesions
  • Smaller vessels
  • Ostial Lesions
  • Diffuse disease

Effective Focused Force Dilatation with Dual Wire System

The dual wire system creates a focal stress pattern to facilitate effective controlled plaque fracture at low resolution pressure.

X-Flex tip and TiFo Folding for Low Crossing Profile

Splendid Crossability

X-Flex tip and TiFo Processing enable unsurpassed crossability.

Flex Zone
Flexible soft tapered tip allows for smooth lesion entry.

Transit Zone
Transit zone provides a balanced support to guide the balloon to pass through the lesion.

Support Zone
Support zone secures the guidewire exit positioning and assists in pushability of the device.

Tight Fold processing results in a slender 
primary profile for enhanced crossability 
through tight lesions.

Designed for Unbeatable Trackability

Soft balloon material combined with elastic nitinol integral wire exhibit exceptional trackability.

Procedural Steps

 

Step 1

Advance a standard guidewire to cross through the target lesion.

 

Step 2

Advance Scoreflex over the guidewire and cross the target lesion. Position the dilatation section of the balloon within the stenosis.

 

Step 3

Begin inflation of Scoreflex at 2 atm and hold at this pressure for 10-20 seconds. Gradually increase pressure in 1 atm steps until the target balloon diameter is achieved. Hold at the final pressure for 20 seconds.

 

Step 4

Withdraw the deflated Scoreflex catheter once the desired result is achieved.

Technical Drawing (Click on the picture to enlarge)


Compliance Chart

 (mm)   PRESSURE (atm)
  4 6* 8 10 12 14 16** 18 20
    NP         RBP    
 
2.0   1.96 2.00 2.04 2.08 2.12 2.16 2.20 2.23 2.27
2.5 2.45 2.50 2.55 2.60 2.65 2.70 2.75 2.80 2.86
3.0 2.94 3.00 3.05 3.11 3.17 3.22 3.28 3.34 3.39
3.5 3.43 3.50 3.57 3.63 3.70 3.76 3.83 3.90 3.96
4.0 3.92 4.00 4.08 4.15 4.23 4.31 4.38 4.46 4.53
                   

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  10 15 20
     
2.0 620-103-1 620-153-1 620-203-1
2.5 625-103-1 625-153-1 625-203-1
3.0 630-103-1 630-153-1 630-203-1
3.5 635-103-1 635-153-1 635-203-1
4.0 640-103-1 640-153-1 640-203-1
Published in Our Brands
Tagged under
Read more...

Sapphire

الأحد, 19 نيسان/أبريل 2015 13:34
Sapphire

 Sapphire Coronary Dilatation Catheter is a balloon that combines advanced new technologies for ultimate crossability. The Sunflex tapered tip is superbly engineered for smooth lesion accessability and ultra low tip profile. With specially formulated Slidematrix dual coating and the enhanced TiFo processing, Sapphire is ideal for lubricious crossing.

The 1.25 mm balloon offers predictable crossability for your most challenging lesions. A truly well balanced performance from hub to tip. The smooth transition zone enhances trackability in tortuous anatomy and enhances visibility from dye injection in complex procedures together with resistance against buckling and kinking which maximizes pushability. The Sapphire 1.25 mm is the first low profile balloon available in 5 mm lengths.

  • Strengthened hypotube and thinner distal shaft
  • ”Zero” transition between the tip and wire for smoothest entry profile


”Zero” transition

Sunflex Tip for Smooth Lesion Accessability

Sunflex tip is superbly engineered to give a perfect balance between flexibility and kink resistance. The tapered soft tip combined with advanced laser welding technology provides the most competitive tip entry profile of 0.016" reducing fish mouthing.

TiFo Folding for Enhanced Crossability in the Tightest Lesions

Tight Fold processing results in a slender primary profile for enhanced crossability through tight lesions.

Slidematrix Dual Coating for Superb Crossability

Slidematrix coating provides an optimal balance providing lubricious crossing and minimizing watermelon seeding. Hydrophilic coating is applied on the tip and Invio coating is applied from the balloon to the proximal exit marker.

Kissing

Technical Drawing (Click on the picture to enlarge)


 

 

Compliance Chart

 (mm)   PRESSURE (atm)
  3 4 5 6* 7 8 9 10 11 12 13 14 15 16** 17 18 19 20
        NP                   RBP        
 
1.25   1.19 1.21 1.23 1.25 1.27 1.29 1.31 1.34 1.36 1.38 1.40 1.42 1.44 1.47 1.49 1.51 1.53 1.55
1.5 1.33 1.40 1.45 1.50 1.54 1.57 1.60 1.63 1.65 1.67 1.69 1.71 1.73 1.75 1.76 1.78 1.79 1.80
2.0 1.84 1.91 1.96 2.00 2.04 2.07 2.09 2.12 2.14 2.16 2.18 2.20 2.21 2.23 2.24 2.25 2.27 2.28
2.25 2.09 2.15 2.21 2.25 2.29 2.32 2.35 2.37 2.39 2.41 2.43 2.45 2.47 2.48 2.49 2.51 2.52 2.53
2.5 2.32 2.39 2.45 2.50 2.54 2.58 2.61 2.63 2.66 2.68 2.70 2.72 2.74 2.76 2.77 2.79 2.80 2.82
2.75 2.53 2.62 2.69 2.75 2.80 2.84 2.88 2.91 2.95 2.97 3.00 3.02 3.05 3.07 3.09 3.10 3.12 3.14
3.0 2.77 2.87 2.94 3.00 3.05 3.10 3.13 3.17 3.20 3.23 3.26 3.28 3.30 3.32 3.34 3.36 3.38 3.40
3.25 3.01 3.11 3.19 3.25 3.30 3.35 3.39 3.43 3.46 3.49 3.52 3.55 3.57 3.59 3.62 3.64 3.65 3.67
3.5 3.21 3.33 3.42 3.50 3.57 3.62 3.67 3.72 3.76 3.79 3.83 3.86 3.89 3.91 3.94 3.96 3.99 4.01
4.0 3.67 3.81 3.91 4.00 4.07 4.14 4.19 4.24 4.29 4.33 4.37 4.41 4.44 4.47 4.50 4.53 4.55 4.58
                                     

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  5 8 10 12 15 20 30
     
1.25 103-1205 103-1208 103-1210 - 103-1215 - -
1.5 - - 103-1510 103-1512 103-1515 103-1520 -
2.0 - - 103-2010 103-2012 103-2015 103-2020 -
2.25 - - 103-2210 - 103-2215 103-2220 -
2.5 - - 103-2510 103-2512 103-2515 103-2520 103-2530
2.75 - - 103-2710 - 103-2715 103-2720 -
3.0 - - 103-3010 103-3012 103-3015 103-3020 103-3030
3.25 - - 103-3210 - 103-3215 103-3220 -
3.5 - - 103-3510 - 103-3515 103-3520 103-3530
4.0 - - 103-4010 - 103-4015 103-4020 -
Published in Our Brands
Tagged under
Read more...

Sapphire NC

الأحد, 19 نيسان/أبريل 2015 13:32
Sapphire NC

Sapphire NC Coronary Dilatation Catheter is a non-compliant balloon dilatation catheter with minimal growth 
and robust rated burst pressure.

 

1. Balloon elongation, especially under high-pressure dilatation, may induce over-dilation of the native artery, proximal and distal to the lesion and subsequently may increase the risk of dissection or restenosis.

Data on file

Sapphire NC combines advanced precision and material engineering technologies for optimum reliability and deliverability.

HIST Tip for Fast and Precise Crossability

HIgh Speed Tracking tip with precision laser technology for leading tip rounding offers speedy and flexible tracking.

TiFo Folding for Enhanced Crossability in the Tightest Lesions

Tight Fold processing results in a slender primary profile for enhanced crossability through tight lesions.

High RBP for Confident Performance

Robust Rated Burst Pressure for confident performance in calcified lesions or for post stent dilatation.

Technical Drawing (Click on the picture to enlarge)


Compliance Chart

 (mm)   PRESSURE (atm)
  6 8 10 12* 14 16 18 20 22** 24 26
        NP         RBP  
 
2.0   1.94 1.96 1.98 2.00 2.02 2.04 2.06 2.08 2.10 2.12 2.14
2.25 2.18 2.20 2.23 2.25 2.27 2.30 2.32 2.35 2.37 2.39 2.42
2.5 2.42 2.44 2.47 2.50 2.53 2.56 2.58 2.61 2.64 2.67 2.70
2.75 2.65 2.69 2.72 2.75 2.78 2.81 2.85 2.88 2.91 2.94 2.97
3.0 2.89 2.93 2.96 3.00 3.04 3.07 3.11 3.14 3.18 3.22 3.25
3.25 3.14 3.17 3.21 3.25 3.29 3.33 3.36 3.40 3.44 3.48 3.52
3.5 3.38 3.42 3.46 3.50 3.54 3.58 3.62 3.66 3.70 3.74 3.78
3.75 3.61 3.66 3.70 3.75 3.80 3.84 3.89 3.93 3.98 4.03 4.07
4.0 3.85 3.90 3.95 4.00 4.05 4.10 4.15 4.20 4.25 4.30 4.35
4.5 4.29 4.36 4.43 4.50 4.57 4.64 4.71 4.77 4.84 4.91 4.98
5.0 4.76 4.84 4.92 5.00 5.08 5.16 5.24 5.31 5.39 5.47 5.55
                       

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  8 10 12 15 18
     
2.0 220-083-2 220-103-2 220-123-2 220-153-2 220-183-2
2.25 222-083-2 222-103-2 222-123-2 222-153-2 222-183-2
2.5 225-083-2 225-103-2 225-123-2 225-153-2 225-183-2
2.75 227-083-2 227-103-2 227-123-2 227-153-2 227-183-2
3.0 230-083-2 230-103-2 230-123-2 230-153-2 230-183-2
3.25 232-083-2 232-103-2 232-123-2 232-153-2 232-183-2
3.5 235-083-2 235-103-2 235-123-2 235-153-2 235-183-2
3.75 237-083-2 237-103-2 237-123-2 237-153-2 237-183-2
4.0 240-083-2 240-103-2 240-123-2 240-153-2 240-183-2
4.5* 245-083-2 245-103-2 245-123-2 245-153-2 245-183-2
5.0* 250-083-2 250-103-2 250-123-2 250-153-2 250-183-2
           

* Available for selected countries

Quantum™ Maverick® is a registered trademark of Boston Scientific Corporation.
NC Sprinter® is a registered trademark of Medtronic, Inc.
Powersail® is a registered trademark of Abbott Vascular.
Dura Star® is a registered trademark of Cordis Corporation.
Kongou® is a registered trademark of Terumo Corporation.

Published in Our Brands
Tagged under
Read more...

Sapphire II

الأحد, 19 نيسان/أبريل 2015 13:31
Sapphire II

Sapphire II Coronary Dilatation Catheter is a well-balanced balloon catheter that crosses lesions without boundaries.

The product is intelligently engineered to fit every need from treating tight lesions to negotiating through tortuous anatomies. The product portfolio includes a new 1.0 mm configuration; this balloon is ideal for penetrating severely narrowed lesions.

Data on file.

XD Shaft for enhanced pushability

Smart engineering combined with innovation delivers the ultimate balanced catheter to cross the most difficult lesions.

XD Shaft is specifically engineered to enhance overall pushability and trackability.

Hydro-X Coating for unparalleled crossability

Sapphire II is coated with the latest Hydro-X Coating technology to deliver ultimate speed and reliability.

The inner lumen is coated with our proprietary blended Invio coating for unsurpassable guidewire tracking.

Z-Tip technology for managing challenging lesions

Not all balloon tips are created equal. Our latest advancement in laser welding technology delivers the best Z-Tip profile, resulting in “ZERO” transition between the tip and the steerable guidewire which is crucial for achieving a smooth yet safe penetration for any complex lesion. Different balloon sizes are matched with different Z-Tip lengths resulting in a balanced catheter for crossing very tight lesions on all occasions.


Z-Tip technology coupled with our proprietary blended soft balloon produces a balanced catheter with a slender crossing profile.

Technical Drawing (Click on the picture to enlarge)


Compliance Chart

 (mm)   PRESSURE (atm)
  2 4 6* 8 10 12 14* 16 18
      NP       RBP    
 
1.0   0.91 0.96 1.00 1.04 1.09 1.13 1.17 1.22 1.26
1.25 1.16 1.20 1.25 1.30 1.34 1.39 1.44 1.48 1.53
1.5 1.40 1.45 1.50 1.55 1.60 1.66 1.71 1.76 1.81
1.75 1.66 1.70 1.75 1.80 1.84 1.89 1.94 1.98 2.03
2.0 1.87 1.94 2.00 2.06 2.13 2.19 2.25 2.32 2.38
2.25 2.11 2.18 2.25 2.32 2.39 2.45 2.52 2.59 2.66
2.5 2.36 2.43 2.50 2.57 2.64 2.71 2.78 2.85 2.92
2.75 2.59 2.67 2.75 2.83 2.91 2.98 3.06 3.14 3.22
3.0 2.82 2.91 3.00 3.09 3.18 3.27 3.36 3.45 3.54
3.25 3.06 3.16 3.25 3.34 3.44 3.53 3.62 3.72 3.81
3.5 3.29 3.39 3.50 3.61 3.71 3.82 3.92 4.03 4.14
4.0 3.77 3.89 4.00 4.11 4.23 4.34 4.45 4.57 4.68
                   

*Nominal Pressure **Rated Burst Pressure – Do Not Exceed

Ordering Information

 (mm)   LENGTH (mm)
  5 8 10 12 15 20 30
140 cm working length
1.0   234-R-1005J 234-R-1008J 234-R-1010J - 234-R-1015J - -
1.25 234-R-1205J 234-R-1208J 234-R-1210J - 234-R-1215J - -
1.5 - - 234-R-1510J 234-R-1512J 234-R-1515J 234-R-1520J -
1.75 - - 234-R-1710J - 234-R-1715J 234-R-1720J -
2.0 - - 234-R-2010J 234-R-2012J 234-R-2015J 234-R-2020J -
2.25 - - 234-R-2210J - 234-R-2215J 234-R-2220J -
2.5 - - 234-R-2510J 234-R-2512J 234-R-2515J 234-R-2520J 234-R-2530J
2.75 - - 234-R-2710J - 234-R-2715J 234-R-2720J -
3.0 - - 234-R-3010J 234-R-3012J 234-R-3015J 234-R-3020J 234-R-3030J
3.25 - - 234-R-3210J - 234-R-3215J 234-R-3220J -
3.5 - - 234-R-3510J - 234-R-3515J 234-R-3520J 234-R-3530J
4.0 - - 234-R-4010J - 234-R-4015J 234-R-4020J -
150 cm working length
1.0   234-RL-1005J 234-RL-1008J 234-RL-1010J - 234-RL-1015J - -
1.25 234-RL-1205J 234-RL-1208J 234-RL-1210J - 234-RL-1215J - -
1.5 - - 234-RL-1510J - 234-RL-1515J 234-RL-1520J -
1.75 - - 234-RL-1710J - 234-RL-1715J 234-RL-1720J -
2.0 - - 234-RL-2010J - 234-RL-2015J 234-RL-2020J -
               

RyujinTM Plus is a registered trademark of Terumo Corporation

Published in Our Brands
Tagged under
Read more...

Azule

الأحد, 19 نيسان/أبريل 2015 13:30
Azule

Dual Helix when Design Matters

The unique Dual Helix design provides natural conformability and tremendous radial strength without compromising its extreme flexibility.

Dual Helix Design


Squared Ends

– for lesion coverage and minimal foreshortening


Dual Helix Backbone

– for flexibility, radial strength and natural conformability


Sinusoidal Rings

– for scaffolding, coverage, and support

http://www.orbusneich.com/image.php?src=images/products/azule/azule_top.jpg&size=600); background-position: 100% 0%; background-repeat: no-repeat;">


Effective Bifurcation Stenting
when Side Branch Access Matters

The Azule Cobalt Chromium Stent cells can be expanded to up to 4.5 mm in diameter, to enable excellent side branch access for effective bifurcation stenting and for maintaining patency of side branches.

Unsurpassed Sidebranchability

 

Cobalt Chromium when Material Matters

Thinner stent struts are better, as long as radial force is not compromised. Thinner metal results in a lower profile, greater flexibility and reduced restenosis, while maintaining adequate radiopacity.1


1. Pache, J, et al., Journal of the American College of Cardiology, April, 2003, 16;41(8):1289-92. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.
Data on file

 

The Azule stent is made from the L605 cobalt chromium alloy, which has no molybdenum and less nickel than 316L stainless steel or MP35N cobalt chromium alloy. Some patients are allergic to both nickel and molybdenum and can develop restenosis as a result.2

 


2. Koster, R, et al., The Lancet, 2000, 356:1895-7. Nickel and Molybdenum Contact Allergies in Patients With Coronary In-stent Restenosis.

Proven Results when Performance Matters


* 3.0 mm diameter stent, data on file

Technical Drawing (Click on the picture to enlarge)


Product Specifications

Stent    
Strut dimensions: 0.0034" (0.09 mm, width) x 0.0032" (0.08 mm, thickness)
Radiopacity: Moderate
Material: L605 cobalt chromium alloy
Side branch access: 4.5 mm
Foreshortening: < 2 %*
Recoil: < 5 %*
Vessel wall coverage: 14 %*
Radial force (to 50% lumen collapse): 26 Psi*

Balloon Catheter
 
Proximal shaft: Hypotube
Nominal pressure: 9 atm
Rated burst pressure: 16 atm
Avg. burst pressure: 31 atm
Nominal crossing profile: 0.038" (0.97 mm)*
Catheter tip length: 5.0 mm
Max. guidewire OD: 0.014"
Shaft (prox/distal): 2.3F/2.9F
Guiding catheter compatibility: 5F (0.056" ID min)
   

*3.0 mm diameter stent

Ordering Information

 (mm)   LENGTH (mm)
  9 13 15 18 23 28 33
     
2.5 225-092-6A 225-132-6A 225-152-6A 225-182-6A 225-232-6A - -
2.75 227-092-6A 227-132-6A 227-152-6A 227-182-6A 227-232-6A - -
3.0 230-092-6A 230-132-6A 230-152-6A 230-182-6A 230-232-6A 230-282-6A 230-332-6A
3.5 235-092-6A 235-132-6A 235-152-6A 235-182-6A 235-232-6A 235-282-6A 235-332-6A
4.0 240-092-6A 240-132-6A 240-152-6A 240-182-6A 240-232-6A 240-282-6A 240-332-6A
               

 

Integrity® and Driver® are registered trademarks of Medtronic, Inc.
Vision™is a trademark of Abbott Vascular.

Published in Our Brands
Tagged under
Read more...
  • البداية
  • السابق
  • 4
  • 3
  • 2
  • 1
  • التالي
  • النهاية
الصفحة 2 من 4

Company Profile

conpany profile png

About Nebras

Contact us
Nebras Co. Ltd. P.O. Box 1235 Amman 11821 / Jordan Telephone no. +962 6 55 20 55 4 Email: عنوان البريد الإلكتروني هذا محمي من روبوتات السبام. يجب عليك تفعيل الجافاسكربت لرؤيته.
Welcome To Our Website
Nebras aims to be the market leader in the field of Biomedical Equipment and Medical Supplies to supply healthcare organizations with latest innovations, best quality…
Partnership
For supplying of pharmaceuticals from different manufacturers in Jordan •Levant - Romania For supplying pharmaco- herbal products 
Future portfolio
•Pharmaceutical products (most of therapeutic groups) •Food supplements •Personal care •Dental care •Nutrients •Medical supplies
Vision & Mission
•NEBRAS Vision:    To be one of the leading marketing and distributing companies in the MENA region. •NEBRAS Mission :    To market and distribute…

Peptest

0999

Professional Staff

We have a proffessional in marketing and sales and distribution.

 

 
 
 

 
 
© Copyright 2015 - Nebras. All rights Reserved
Developed By Just Click Solutions 
Back top