Print this page

Azule

Dual Helix when Design Matters

The unique Dual Helix design provides natural conformability and tremendous radial strength without compromising its extreme flexibility.

Dual Helix Design


Squared Ends

– for lesion coverage and minimal foreshortening


Dual Helix Backbone

– for flexibility, radial strength and natural conformability


Sinusoidal Rings

– for scaffolding, coverage, and support

http://www.orbusneich.com/image.php?src=images/products/azule/azule_top.jpg&size=600); background-position: 100% 0%; background-repeat: no-repeat;">


Effective Bifurcation Stenting
when Side Branch Access Matters

The Azule Cobalt Chromium Stent cells can be expanded to up to 4.5 mm in diameter, to enable excellent side branch access for effective bifurcation stenting and for maintaining patency of side branches.

Unsurpassed Sidebranchability

 

Cobalt Chromium when Material Matters

Thinner stent struts are better, as long as radial force is not compromised. Thinner metal results in a lower profile, greater flexibility and reduced restenosis, while maintaining adequate radiopacity.1


1. Pache, J, et al., Journal of the American College of Cardiology, April, 2003, 16;41(8):1289-92. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.
Data on file

 

The Azule stent is made from the L605 cobalt chromium alloy, which has no molybdenum and less nickel than 316L stainless steel or MP35N cobalt chromium alloy. Some patients are allergic to both nickel and molybdenum and can develop restenosis as a result.2

 


2. Koster, R, et al., The Lancet, 2000, 356:1895-7. Nickel and Molybdenum Contact Allergies in Patients With Coronary In-stent Restenosis.

Proven Results when Performance Matters


* 3.0 mm diameter stent, data on file

Technical Drawing (Click on the picture to enlarge)


Product Specifications

Stent    
Strut dimensions: 0.0034" (0.09 mm, width) x 0.0032" (0.08 mm, thickness)
Radiopacity: Moderate
Material: L605 cobalt chromium alloy
Side branch access: 4.5 mm
Foreshortening: < 2 %*
Recoil: < 5 %*
Vessel wall coverage: 14 %*
Radial force (to 50% lumen collapse): 26 Psi*

Balloon Catheter
 
Proximal shaft: Hypotube
Nominal pressure: 9 atm
Rated burst pressure: 16 atm
Avg. burst pressure: 31 atm
Nominal crossing profile: 0.038" (0.97 mm)*
Catheter tip length: 5.0 mm
Max. guidewire OD: 0.014"
Shaft (prox/distal): 2.3F/2.9F
Guiding catheter compatibility: 5F (0.056" ID min)
   

*3.0 mm diameter stent

Ordering Information

 (mm)   LENGTH (mm)
  9 13 15 18 23 28 33
     
2.5 225-092-6A 225-132-6A 225-152-6A 225-182-6A 225-232-6A - -
2.75 227-092-6A 227-132-6A 227-152-6A 227-182-6A 227-232-6A - -
3.0 230-092-6A 230-132-6A 230-152-6A 230-182-6A 230-232-6A 230-282-6A 230-332-6A
3.5 235-092-6A 235-132-6A 235-152-6A 235-182-6A 235-232-6A 235-282-6A 235-332-6A
4.0 240-092-6A 240-132-6A 240-152-6A 240-182-6A 240-232-6A 240-282-6A 240-332-6A
               

 

Integrity® and Driver® are registered trademarks of Medtronic, Inc.
Vision™is a trademark of Abbott Vascular.