• Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us
  • Home
  • Who we are
  • Products
    • Peptest
    • FIT-Fecal Immunochemical Test
    • Bladder Tumor Antigen Test Cassette
    • GR Cast
  • Vision & Mission
  • Partnership
  • Future portfolio
  • Contact Us

Super User

  • Home 
  • Future portfolio 
  • Super User
Super User

Super User

Genous Stainless Steel

الأحد, 19 نيسان/أبريل 2015 13:28
Genous Stainless Steel

Genous promotes tissue healing of stent-related injuries in a rapid and controlled manner, unlike drug eluting stents, which indiscriminately inhibit healing reactions using anti-proliferative drugs. Genous captures circulating endothelial progenitor cells (EPCs) to accelerate natural healing. This innovative approach protects against thrombosis and minimizes restenosis. Welcome to the new era of Bio-engineered stents.

Plan for the best – Insure against the worst

Bone marrow derived EPCs 
circulate in the blood stream.
Genous with anti-hCD34 
antibody on the stent surface captures EPCs.
EPCs mature into endothelial cells, healing the artery with restored endothelium.

Accelerated Natural Healing

A unique surface priming process prepares a functionalized surface on the bare metal stent. The following bio-chemical reaction results in a biocompatible intermediate matrix. Covalent bonding then achieves antibody attachment. EPCs originate from bone marrow and circulate through the bloodstream. EPCs are captured by antibodies and immobilized on the stent surface. EPC capture, division, and migration continue until a confluent functional endothelial layer is formed between the stent struts.

Stent coating process

The role of endothelium is to:

  • Act as a barrier to prevent thrombus formation
  • Regulate permeability
  • Modulate smooth muscle cell growth
  • Produce vasoactive compounds

Unique stent design – innovation that matters

To give the Genous concept an appropriate stent platform, we employ our uniquely designed coronary R stent. Its patented dual helix configuration provides omni-directional flexibility and extremely high radial strength. The stent's cells can be expanded to up to 4.5 mm in diameter, to enable excellent side branch access for bifurcation stenting.

Up to 4.5 mm side branch access

Stent design at an unprecedented level

Technical Drawing (Click on the picture to enlarge)


Product Specifications

Stent    
Strut dimensions: 0.0035" (0.09 mm) x 0.0040" (0.10 mm)
Radiopacity: Moderate
Material: 316L stainless steel
Side branch access: 4.5 mm
Foreshortening: < 1 %*
Recoil: < 4 %*
Vessel wall coverage: 17 %*
Radial force (to collapse): > 25 psi*

Balloon Catheter
 
Proximal shaft: Hypotube
Nominal pressure: 9 atm
Rated burst pressure: 16 atm
Avg. burst pressure: 27 atm*
Nominal crossing profile: 0.043" (1.09 mm)*
Catheter tip length: 5.0 mm
Max. guidewire OD: 0.014"
Shaft (prox/distal): 2.2F/2.9F
Guiding catheter compatibility: 5F (0.057" ID min) for 2.5, 2.75 mm and
6F (0.068" ID min) for 3.0, 3.5, and 4.0 mm
   

* 3.0 mm diameter stent

Ordering Information

 (mm)   LENGTH (mm)
  9 13 15 18 23 28 33
     
2.5 225-092-5 225-132-5 225-152-5 225-182-5 225-232-5    
2.75 227-092-5 227-132-5 227-152-5 227-182-5 227-232-5    
3.0 230-092-5 230-132-5 230-152-5 230-182-5 230-232-5 230-282-5 230-332-5
3.5 235-092-5 235-132-5 235-152-5 235-182-5 235-232-5 235-282-5 235-332-5
4.0 240-092-5 240-132-5 240-152-5 240-182-5 240-232-5 240-282-5 240-332-5
Published in Our Brands
Tagged under
Read more...

Genous CoCr

الأحد, 19 نيسان/أبريل 2015 13:27
Genous CoCr

Plan for the best – Insure against the worst

Bone marrow derived EPCs 
circulate in the blood stream.

Genous with anti-hCD34 
antibody on the stent surface captures EPCs.

EPCs mature into endothelial cells, healing the artery with restored endothelium.

Design Matters

The Genous Bio-engineered Cobalt Chromium Stent has a unique dual helix design that provides natural conformability and tremendous radial strength without compromising its extreme flexibility.


Squared Ends

– for lesion coverage and minimal foreshortening


Dual Helix Backbone

– for flexibility, radial strength and natural conformability


Sinusoidal Rings

– for scaffolding, coverage, and support

Unsurpassed Sidebranchability

Up to 4.5 mm side branch access for effective bifurcation stenting and for maintaining patency of side branches.

Material Matters

The Genous CoCr stent is made from the L605 cobalt chromium alloy, which has no molybdenum and less nickel than 316L stainless steel and MP35N cobalt chromium alloy. Some patients are allergic to both nickel and molybdenum and can develop restenosis as a result.1

1. Koster, R, et al., The Lancet, 2000, 356:1895-7. Nickel and Molybdenum Contact Allergies in Patients With Coronary In-stent Restenosis.

Thinner is Better

Thinner stent struts are better, as long as radial force is not compromised. Thinner metal results in a lower profile, greater flexibility, and reduced restenosis.2

2. Pache, J, et al., Journal of the American College of Cardiology, April, 2003, 16;41(8):1289-92. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.

Technical Drawing (Click on the picture to enlarge)


Product Specifications

Stent    
Strut dimensions: 0.0034" (0.09 mm, width) x 0.0032" (0.08 mm, thickness)
Radiopacity: Moderate
Material: L605 cobalt chromium alloy
Side branch access: 4.5 mm
Foreshortening: < 2 %*
Recoil: < 5 %*
Vessel wall coverage: 14 %*
Radial force (to 50% lumen collapse): 26 Psi*

Balloon Catheter
 
Proximal shaft: Hypotube
Nominal pressure: 9 atm
Rated burst pressure: 16 atm
Avg. burst pressure: > 28 atm
Nominal crossing profile: 0.038" (0.97 mm)*
Catheter tip length: 4.25 mm
Max. guidewire OD: 0.014"
Shaft (prox/distal): 2.3F/2.9F
Guiding catheter compatibility: 5F (0.056" ID min)
   

*3.00 mm diameter stent

Ordering Information

 (mm)   LENGTH (mm)
  9 13 15 18 23 28 33
     
2.5 225-092-7 225-132-7 225-152-7 225-182-7 225-232-7    
2.75 227-092-7 227-132-7 227-152-7 227-182-7 227-232-7    
3.0 230-092-7 230-132-7 230-152-7 230-182-7 230-232-7 230-282-7 230-332-7
3.5 235-092-7 235-132-7 235-152-7 235-182-7 235-232-7 235-282-7 235-332-7
4.0 240-092-7 240-132-7 240-152-7 240-182-7 240-232-7 240-282-7 240-332-7
         
Published in Our Brands
Tagged under
Read more...

Orbusneich

الأحد, 19 نيسان/أبريل 2015 13:22
Orbusneich

The Genous Bio-engineered surface features antibodies immobilized on the stent that capture circulating endothelial progenitor cells (EPCs), which in turn rapidly form an endothelial layer over and between the stent struts. This protects against thrombus and minimizes restenosis.

Published in Our Brands
Tagged under
Read more...

Welcome To Our Website

الأحد, 19 نيسان/أبريل 2015 11:17

Nebras aims to be the market leader in the field of Biomedical Equipment and Medical Supplies to supply healthcare organizations with latest innovations, best quality and value added products to Jordan and Middle East's communities and to share in developing the healthcare industry in the Middle East. Nebras works constantly to improve customer satisfaction, and employee opportunity and shareholder value.

Published in About Nebras Jordan
Tagged under
Read more...

Partnership

الخميس, 16 نيسان/أبريل 2015 07:09

For supplying of pharmaceuticals from different manufacturers in Jordan

•Levant - Romania

For supplying pharmaco- herbal products 

Published in About Nebras Jordan
Tagged under
Read more...
  • البداية
  • السابق
  • 4
  • 3
  • 2
  • 1
  • التالي
  • النهاية
الصفحة 3 من 4

Company Profile

conpany profile png

About Nebras

Contact us
Nebras Co. Ltd. P.O. Box 1235 Amman 11821 / Jordan Telephone no. +962 6 55 20 55 4 Email: عنوان البريد الإلكتروني هذا محمي من روبوتات السبام. يجب عليك تفعيل الجافاسكربت لرؤيته.
Welcome To Our Website
Nebras aims to be the market leader in the field of Biomedical Equipment and Medical Supplies to supply healthcare organizations with latest innovations, best quality…
Partnership
For supplying of pharmaceuticals from different manufacturers in Jordan •Levant - Romania For supplying pharmaco- herbal products 
Future portfolio
•Pharmaceutical products (most of therapeutic groups) •Food supplements •Personal care •Dental care •Nutrients •Medical supplies
Vision & Mission
•NEBRAS Vision:    To be one of the leading marketing and distributing companies in the MENA region. •NEBRAS Mission :    To market and distribute…

Peptest

0999

Professional Staff

We have a proffessional in marketing and sales and distribution.

 

 
 
 

 
 
© Copyright 2015 - Nebras. All rights Reserved
Developed By Just Click Solutions 
Back top